Would like to know what could be the problem here and the steps I can take to solve this issue. If the error recurs, please note all circumstances and contact Informix Technical Support. -49 Can't assign requested address. An operating or runtime system error or a driver internal error occurred. Fix the ONCONFIG file so that the parameter is 0/1. 38095 string is invalid setting for ADTMODE. http://mttags.com/informix-error/informix-error-code-79716.php

An operating-system error code with the meaning shown was unexpectedly returned to the database server. If another sqlexecd daemon or database server on the network already uses the name, use a different service name to start the sqlexecd daemon. And why? If you are using the TCP/IP protocol, check that the correct service name appears in the /etc/services file. http://members.iiug.org/forums/ids/index.cgi/read/29752

Force some sort of traffic through the connection so that the firewall doesn't think the connection is stale As mentioned, the first option is usually not considered possible. This error probably reflects a limit that was configured in your operating system. Enter your request again. If the error recurs, please note all circumstances and contact Informix Technical Support. -9 Bad file number.

  1. The initial number of VPs specified by a VPCLASS parameter is greater than the maximum specified by the same VPCLASS parameter.
  2. It might be missing or have incorrect permission values.
  3. Use this SQLCODE value to determine when a statement reaches the end of the data.
  4. An operating-system error code with the meaning shown was unexpectedly returned to the database server.
  5. Felizmente os sistemas operativos já dispõem de um mecanismo que testa as conexões, o qual é chamado de "keepalive" ou "keepalive probes".
  6. informix jdbc multiple-outer-join syntax error 8.
  7. The onspaces command that you used to drop the external space was successful. 33990 External space drop fails.
  8. Ao receber este sinal a aplicação sabe que a conexão foi fechada e pode tomar as ações apropriadas, como recriá-la ou gerar um erro.

Contact your system administrator if you need help setting these environment variables. 1204 Your system encountered an unknown type of terminal. Another option on some application servers would be to "test" the connections (usually requires some dummy and simple query), or define a maximumage for the connections. It is not an error. 32728 Clock setting check not available in daemon. If the error recurs, please note all circumstances and contact Informix Technical Support. -39 Destination address required.

Edit the load file and try again. 38061 Actions must be the first argument to onaudit. An operating-system error code with the meaning shown was unexpectedly returned to the database server. Re: JDBC-System or internal error java.io.IOExcept (views: 481)Mark Tyrer -- Thursday, 14 March 2013, at 7:51 a.m. Muitas vezes aparece também a seguinte mensagem: java.net.SocketException: Broken pipe Se encontrar isto, a probabilidade é que exista um firewall entre o servidor aplicacional e a base de dados que esteja

Look for other operating-system error messages that might give more information. The specified error(s) involves the indicated tables. 4074 Cannot find a C language compiler in any directory in your path. The specified file cannot be created. Read 16 May 11 - Business Wire - HiT Software Announces DBMoto for Enterprise Integration, Adds Informix.

If not, please note all circumstances and contact Informix Technical Support. -65 Host is unreachable. An operating-system error code with the meaning shown was unexpectedly returned to the database server. In Response To: Re: JDBC-System or internal error java.io.IOExcept (KARTHIK RAJAN) I meant the error on the client. Retry this operation later. 32718 License file does not support this version.

You must include one or more table names in the TABLES section of the form-specification file. 2020 The following tables are involved in an error: table-name. check over here Read 6 Feb 12 - PRLOG - Informix port delivers unlimited database scalability for popular SaaS application ... Log in as root or informix before you attempt the backup, restore, or database logging mode change. 43019 User is not a member of the Informix-Admin group. Please consult the Installation Instructions.

One of our tables has two TEXT colums but when we attempt to fill these columns using a PLS/stored procedure which is driven by a java servlet, we get a null Either edit the load file or delete the existing definition. 38084 OS mode auditing not supported for this platform. For example: To see what the current setting is: /usr/sbin/no -o tcp_nodelayack To disable this feature without making it permanent: /usr/sbin/no -o tcp_nodelayack=0 To make the change persistent across reboots: /usr/sbin/no his comment is here Read 19 May 10 - ZDNet - IBM software in your home?

Delete the row and then insert a new row with the new primary key. 43012 Unable to open connection to server. So you need to update the the ID of kaushal 2. If the error recurs, please note all circumstances and contact Informix Technical Support. -50 Network is down.

Check the license file to ensure that the version of the desired product on the feature line is the same as or later than the version that you want to use.

Read 3 Oct 12 - The Financial - IBM and TransWorks Collaborate to Help Louisiana-Pacific Corporation Achieve Supply Chain Efficiency... Note all observed behavior and any other error message. Enter your request again. The table has not been created or was deleted.

Look for other operating-system error messages that might give more information. -68 Too many users. Read 21 May 10 - CNET - IBM to help people monitor energy use... The present date exceeds the expiration date of the feature in the license file. weblink And that is a bit more complex to explain but trivial to implement.

An operating-system error code with the meaning shown was unexpectedly returned to the database server. The service name of each database server must be unique across the entire NetWare network. Nunca presenciei uma situação onde tal acontecesse. Re: JDBC-System or internal error java.io.IOExcept (views: 455)KARTHIK RAJAN -- Thursday, 14 March 2013, at 8:06 a.m.

If the error recurs, please refer to the Appendix entitled "Trapping Errors" in your Administrator's Guide to acquire additional diagnostics. An operating-system error code with the meaning shown was unexpectedly returned to the database server. Verify that the storage space exists in this database server. 43043 Must restore logical logs from date_time or later. The affinity specification for the VPCLASS line is incorrect.